The first inspection and testing is carried out either before a t… . (g) electrically-powered equipment not permanently installed in the mine but required occasionally for monitoring, testing, recording and measurement, and used where the concentration of firedamp is 0.8% by volume or less in accordance with suitable rules drawn up by the manager to ensure that danger will not thereby arise, which rules shall in particular include provision for personal supervision of that equipment by a competent person and testing for firedamp when it is in use; Restriction of equipment in certain zones below ground. If a circuit conductor is connected to earth or to any other reference point, nothing which might reasonably be expected to give rise to danger by breaking the electrical continuity or introducing high impedance shall be placed in that conductor unless suitable precautions are taken to prevent that danger. NZS 3760 is cited in the electrical regulations as a means of … Electrical equipment using oil as a means of cooling, insulation or arc suppression shall not be introduced below ground at a mine. At any mine in which electrical storage batteries are used below ground, those batteries shall, so far as is reasonably practicable, be used, stored, charged and transferred in a safe manner. 23. (d) any flammable or explosive substance, including dusts, vapours or gases. Please see the Electrical Testing menu above for a complete description of Electrical Testing & safety in the place of work and in your home .In particular how and why we test the way we do. 24.—(1) Suitable schematic diagrams of all electrical distribution systems intended to be operated at the mine (other than those operating at a voltage not exceeding 250 volts) shall, so far as is reasonably practicable-. (3) In the Mines and Quarries Act 1954, the Mines and Quarries (Tips) Act 1969 and the Mines Management Act 1971, and in regulations made under any of those Acts, or in health and safety regulations, any reference to any of those Acts shall be treated as including a reference to these Regulations. Related products Memorandum of guidance on the Electricity at Work Regulations 1989 Act 1974 apply by virtue of Articles 6 and 7 of the Health and Safety at Work etc. (3) Plans on a suitable scale shall be kept in the office at the mine showing, so far as is reasonably practicable, the position of all permanently installed electrical equipment at the mine supplied at a voltage in excess of 250 volts. Our periodic inspection and testing of fixed electrical installations will support you in complying with these standards, including regulation 4 of the Electricity at Work Regulations 1989, which requires that: ‘As may be necessary to prevent danger, all systems shall be maintained so as to prevent such danger.’ Where danger may exist, all systems should be constructed and maintained in a safe condition, and records … . Electrical safety testing ,Southern testing. Each circuit while it is being tested needs to be de-energised while the test takes place. (2) Expressions to which meanings are assigned by the Mines and Quarries Act 1954 shall, unless the contrary intention appears, have the same meanings in regulations 18 to 27 and Schedule 1. These Regulations may be cited as the Electricity at Work Regulations 1989 and shall come into force on 1st April 1990. Electrical loa… (2) Nothing in paragraph (1) shall prevent the taking or use below ground at any safety-lamp mine of any electrical equipment which was, before the coming into force of these Regulations, approved pursuant to regulations 20 and 21A of the Coal and Other Mines (Electricity) Regulations 1956. The Regulations require landlords to have the electrical installations in their properties inspected and tested by a person who is qualified and competent, at least every 5 years. (3) Paragraph (1) shall not apply to electrical equipment which is itself a source of electrical energy but, in such a case as is necessary, precautions shall be taken to prevent, so far as is reasonably practicable, danger. Fixed electrical wiring inspection and testing 2. Signed by order of the Secretary of State. 31. (b) show the planned settings of any circuit electrical protective devices. (a) cutting off the supply of electrical energy to any electrical equipment; and. (b) the isolation of any electrical equipment. There are a number of elements to a good electrical installation Read more » This leaflet is aimed at people who manage or carry out electrical testing, and gives guidance on controlling risks and preventing or reducing danger arising from these activities. In any proceedings for an offence consisting of a contravention of regulations 4(4), 5, 8, 9, 10, 11, 12, 13, 14, 15, 16 or 25, it shall be a defence for any person to prove that he took all reasonable steps and exercised all due diligence to avoid the commission of that offence. However, this interval may be reduced by the inspector if there are any concerns regarding the installation. (2) Copies of such portions of the schematic diagrams prepared pursuant to paragraph (1) as are necessary to prevent danger and which show at least those parts of the electrical system which are served by switchgear operating at a voltage in excess of 250 volts shall be displayed at each place where such switchgear is installed. This might not have been covered in the report so they have noted it separately as code FI. Periodic inspection and testing should be carried out only by electrically competent persons, such as registered electricians. We use cookies so that you can view all the features and functionality of our website. At Wellington this 1st day of March 2010. (b) the effects of the weather, natural hazards, temperature or pressure; (c) the effects of wet, dirty, dusty or corrosive conditions; or. (2) As may be necessary to prevent danger, all systems shall be maintained so as to prevent, so far as is reasonably practicable, such danger. The duties imposed by these Regulations shall not extend to-. The Regulations require local housing authorities to enforce the duties, and include a power to arrange remedial action. (b) any other requirements imposed by or under any enactment which apply to the case. 6. Regular testing of a building’s wiring structure and maintenance is mandatory by law under The Electricity at Work Regulations 1989 and IET Wiring Regulations BS 7671:2008. Emergency lighting inspection and test to BS 5266 standard 8. (3) Every work activity, including operation, use and maintenance of a system and work near a system, shall be carried out in such a manner as not to give rise, so far as is reasonably practicable, to danger. As such, many electrical components, products and systems have to be tested or certified to government regulations and industry standards such as IEEE and UL. 1. (a) be prepared and kept in the office at the mine; and. (3) If the supply of electricity to electrical equipment is cut off or the equipment made safe in accordance with paragraph (1), details of the time, duration and location shall be recorded. In April … The new 2020 regulations require the electrical installation to be inspected and tested at intervals, not exceeding five years. Risk assessments of fixed electrical installations 4. Top Produit Electrical Testing Regulations pas cher sur Aliexpress France ! Read more », What you should consider before undertaking electrical work Read more », Copyright Read more », An explanation of the Part P regulations Intervals for testing specified electrical equipment The type of work being performed determines how often specified electrical equipment is tested. 20.—(1) Where any person at a mine detects firedamp in a concentration exceeding 1.25% by volume in the general body of the air either below ground at that mine or at any place on the surface thereat where any exhauster in a firedamp drainage system is installed, firedamp is monitored or its heat content measured, he shall forthwith-except that the provisions of sub-paragraphs (a) to (c) above shall not apply if the electrical equipment is approved for the purpose of remaining energised in such circumstances or (in the case of a safety-lamp mine) is electrical equipment such as is specified in regulation 21(2). All conductors in a system which may give rise to danger shall either-. Present: His Excellency the Governor-General in Council. Read more », There are a number of elements to a good electrical installation To achieve compliance with the legal requirements of the Electricity at Work Regulations 1989 requires proof that an electrical system is safe, which involves amongst other things, proper inspection and testing of a system by competent people and the creation and maintenance of records. Where necessary to prevent danger, every joint and connection in a system shall be mechanically and electrically suitable for use. 18. Portable electrical appliance testing 3. Efficient means, suitably located, shall be provided for protecting from excess of current every part of a system as may be necessary to prevent danger. (2) If the supply of electricity to electrical equipment is cut off or the equipment made safe in accordance with paragraph (1), it shall remain in that condition until the senior official on duty at the mine having determined that it is safe to do so, directs that such precautions are no longer necessary. If you continue browsing we'll assume that you agree to accept cookies from the NICEIC website. Every electrical installation in the residential premises is inspected and tested by a qualified person at regular intervals of at least every five years, or more often if specified in an inspection report. (a) be suitably covered with insulating material and as necessary protected so as to prevent, so far as is reasonably practicable, danger; or. A record of testing must be kept until the electrical equipment is next tested, permanently removed from the workplace or disposed of. Electrical Safety Regulations to come into force Tuesday 14 January 2020 Subject to approval by both Houses of Parliament landlords and agents will need to ensure electrical installation inspections and testing are carried out for all new tenancies in England from … The duties do not apply to landlords of social housing. We can usually offer a very quick service if it is required with night time working if day time access is limited due to business requirements. Introduction of battery-powered locomotives and vehicles into safety-lamp mines. 19.—(1) At every safety-lamp mine containing any zones below ground in which firedamp whether or not normally present is likely to occur in a quantity sufficient to indicate danger, there shall be prepared a suitable plan identifying such zones. For the purposes of enabling injury to be prevented, adequate working space, adequate means of access, and adequate lighting shall be provided at all electrical equipment on which or near which work is being done in circumstances which may give rise to danger. To achieve compliance with the legal requirements of the Electricity at Work Regulations 1989 requires proof that an electrical system is safe, which involves amongst other things, proper inspection and testing of a system by competent people and the creation and maintenance of records. Electrical Safety Regulation 2013. Systems, work activities and protective equipment4.—(1) All systems shall at all times be of such construction as to prevent, so far as is reasonably practicable, danger. . 8. Read more », Electrical work is certificated to record the performance of the installation at a point in time Bahrain: Electricity Regulations and Guide for Electrical Contractors; Kuwait: Regulation for electrical installations MEW/R-1 to MEW/R-8 and MEW/S-1; Kingdom of Saudi Arabia: Saudi Building Code (SBC) Requirements, Section 401 – Electrical (SBC 401) Australia/New Zealand. Electrical safety standards are met during any period when the residential premises are occupied by a specified tenancy. Electrical Testing Regulations. Electricity at Work Regulations 1989 is law in the United Kingdom. Since 2005, all electrical work in dwellings in England and Wales whether carried out professionally or as DIY, and whether or not the work is notifiable to a building control body (see below), must meet the requirements of Part P of the Building Regulations. Persons on whom duties are imposed by these Regulations, 3.—(1) Except where otherwise expressly provided in these Regulations, it shall be the duty of every-(a) employer and self-employed person to comply with the provisions of these Regulations in so far as they relate to matters which are within his control; and, (2) It shall be the duty of every employee while at work-(a) to co-operate with his employer so far as is necessary to enable any duty placed on that employer by the provisions of these Regulations to be complied with; and. No person shall be engaged in any work activity where technical knowledge or experience is necessary to prevent danger or, where appropriate, injury, unless he possesses such knowledge or experience, or is under such degree of supervision as may be appropriate having regard to the nature of the work. READ MORE No locomotive or vehicle which uses an electrical storage battery, either partly or wholly, as a power source for traction purposes shall be introduced below ground at a safety-lamp mine unless it is an approved locomotive or vehicle. Electrical equipment which may reasonably foreseeably be exposed to-shall be of such construction or as necessary protected as to prevent, so far as is reasonably practicable, danger arising from such exposure. 2. 28. We recommend that landlords regularly carry out portable appliance testing (PAT) on any electrical appliance that they provide and then supply tenants with a record of any electrical inspections carried out as good practice. (ii) more than 0.25% by volume of firedamp is found on any occasion at any place below ground in the mine; (a) a numbered regulation or Schedule is a reference to the regulation or Schedule in these Regulations so numbered; (b) a numbered paragraph is a reference to the paragraph so numbered in the regulation or Schedule in which the reference appears. We offer the following services - Periodic Inspection and Testing, Electrical Installation Testing, Emergency Lighting Testing, Portable Appliance Testing, Thermographic Surveys, Load Testing. (a) it is unreasonable in all the circumstances for it to be dead; and, (b) it is reasonable in all the circumstances for him to be at work on or near it while it is live; and. Domestic electrical testing Remember that your household insurance will require you have a EICR (test certificate) for your electrical installation. Code C3. 25. . 9. Drawings, tracing, labelling and schedules of electrical installations 5. Electricity (Safety) Regulations 2010 (SR 2010/36) Anand Satyanand, Governor-General. You should be aware that to do the electrical testing the entire installation needs to be de-energised for 5 minutes (do you have a server?). These Regulations shall apply to and in relation to premises and activities outside Great Britain to which sections 1 to 59 and 80 to 82 of the Health and Safety at Work etc. Third-Party Independent Electrical Testing Laboratories ensure the safety and compliance of electrical products and systems by testing, inspection and certification. (2) The enactments and instruments specified in Part II of Schedule 2 shall be modified to the extent specified in that Part. 33.—(1) The instruments specified in column 1 of Part I of Schedule 2 are revoked to the extent specified in the corresponding entry in column 3 of that Part. This means that your electrical testing engineer has observed something whilst carrying out the testing, for instance if the emergency lights seem very dim. What is legally required is that equipment is electrically safe and maintained in a safe condition. However, it's not mandatory. . Electrical work is subject to certain regulations and standards The Electricity at Work regulations 1989 for example impose duties on “employers” and “duty holders” in respect to electrical systems, electrical equipment and conductors. 32. 182 Procedure for obtaining item of in- scope electrical equipment for testing 134 183 Identification of item of in-scope electrical equipment to be tested 135 184 Cost of testing and examining and liability for damage . 26. 17.—(1) The provisions of regulations 18 to 28 and Schedule 1 shall apply to mines only; and the provisions of that Schedule shall have effect in particular in relation to the use below ground in a coal mine of any film lighting circuit (as defined by paragraph 1 of that Schedule) at or in close proximity to a coal face. Electrical Safety Regulation 2013. The frequency of testing required for compliance varies between environments, determined by a number of factors such as the use, operation and other external influences affecting the installation. You can view our cookie policy here for more information. (a) cut off the supply of electricity to any electrical equipment situated at the place where the said concentration was detected; or, (b) (where this is not possible) take all reasonably practicable steps to make such equipment safe; or. (c) suitable precautions (including where necessary the provision of suitable protective equipment) are taken to prevent injury. The law simply requires that all electrical systems must be maintained to be safe at all times. A record of testing must specify: the name of the person who carried out the testing. Under the regulations, landlords need to ensure that: 1. Means for cutting off the supply and for isolation, 12.—(1) Subject to paragraph (3), where necessary to prevent danger, suitable means (including, where appropriate, methods of identifying circuits) shall be available for-. Understanding electrical testing regulations can be quite difficult at times, as there is no actual "legal requirement" although the law does require that all business owners, directors or managers and employees comply with “The Electricity at Work Regulations”. The law requires that all business owners, their directors, managers and employees comply with “The Electricity at Work Regulations”. "system" means an electrical system in which all the electrical equipment is, or may be, electrically connected to a common source of electrical energy, and includes such source and such equipment. We are situated on the Kent, Sussex and Surrey borders.This electrical testing site has been designed and built by GadSolutions and is hosted on one of their servers. the main reasons, to test a new electrical installation or house wiring before it … . There is little point in setting up Regulations to control the way in which domestic electrical installations are designed and installed if it is not verified that they have been followed. 2020 Electrical Installation Testing (periodic inspection & testing) All aspects of the electrical installation are inspected and tested for strength, integrity amd compliance with the IEE Regulations in force at the time the system was installed and to the current regulations where applicable. What makes a good electrical installation. 21.—(1) Subject to paragraph (2), no electric safety-lamp, gas detector, telephone or signalling equipment or other equipment associated therewith or required for the safety of persons shall be taken or used below ground at any safety-lamp mine unless it is equipment which has been approved pursuant to regulation 20(1) or (in the case of electric safety-lamps) is of a type for the time being approved pursuant to section 64(2) of the Mines and Quarries Act 1954. All aspects of an electrical installation are inspected and tested for compliance with BS7671 17th Edition of the IEE Wiring Regulations. 11. Company number OC379918, Guide to Roles and Responsibilities of QS. Read more », Just because an installation is old, doesn't mean its unsafe Note. 13. Insulation, protection and placing of conductors, 7. 136 Division 10 Return of in-scope electrical equipment given to regulator . Code of Practice for the Electricity (Wiring) Regulations. We offer a comprehensive range of trusted electrical equipment inspection services to help achieve compliance with the IET wiring regulations (BS7671), including: 1. (2) In paragraph (1), "isolation" means the disconnection and separation of the electrical equipment from every source of electrical energy in such a way that this disconnection and separation is secure. Act 1974 (Application outside Great Britain) Order as they apply within Great Britain. Adequate precautions shall be taken to prevent electrical equipment, which has been made dead in order to prevent danger while work is carried out on or near that equipment, from becoming electrically charged during that work if danger may thereby arise. Changes authorised by subpart 2 of Part 2 of the Legislation Act 2012 have been made in this official reprint. Order in Council. The regulations as stated below are an overview of the UK regulations. Before electrical equipment (other than equipment approved for the purposes of regulation 20(1)) is first introduced into any underground part of a safety-lamp mine to which the Coal and Other Mines (Surveyors and Plans) Regulations 1956 apply, the manager shall submit to an inspector a copy of the ventilation plan required to be kept for that part by regulation 9 of those Regulations, on which the intended locations of that equipment shall be shown, together with a copy of any schematic diagram relating to that part prepared for the purposes of regulation 24(1). We work weekends if it is required, and can liaise with production staff if a maintenance shut down is planned. Electrical Safety Testing. Section 157 of the Mines and Quarries Act 1954 (which provides a defence in legal proceedings and prosecutions in certain circumstances) shall not apply in relation to any legal proceedings or prosecutions based on an allegation of a contravention of a requirement or prohibition imposed by regulations 18 to 27 or by or under Schedule 1. Storage, charging and transfer of electrical storage batteries. Electrical work is certificated to record the performance of the installation at a point in time Read more » What makes a good electrical installation? For a comprehensive guide please refer to the latest version of the HSE document "Memorandum of Guidance on the Electricity At Work Regulations" - available from HMSO or technical bookshops. Electrical testing and tagging to the NZS 3760 standard verifies compliance with your obligations. 3. Except for production lines normal businesses can carry on with minimal disruption. Electrical safety auditing 7. (a) the master or crew of a sea-going ship or to the employer of such persons, in relation to the normal ship-board activities of a ship's crew under the direction of the master; or. 15. 30.—(1) Subject to paragraph (2), the Health and Safety Executive may, by a certificate in writing, exempt-or any class of the above, from any requirement or prohibition imposed by these Regulations and any such exemption may be granted subject to conditions and to a limit of time and may be revoked by a certificate in writing at any time. Strength and capability of electrical equipment. (c) (if the taking of the measures specified in sub-paragraphs (a) and (b) above does not fall within the scope of his normal duties) report the matter to an official of the mine who shall ensure that those measures are taken; Cutting off electricity or making safe where firedamp is found either below ground or at the surface. (b) have such precautions taken in respect of them (including, where appropriate, their being suitably placed) as will prevent, so far as is reasonably practicable, danger. No electrical equipment shall be put into use where its strength and capability may be exceeded in such a way as may give rise to danger. Thermographic surveys 6. Approval of certain equipment for use in safety-lamp mines. The Electrical Equipment (Safety) Regulations 1994 were revoked on 8 December 2016 but continue to apply to relevant products placed on the market prior to … 10. Certsure LLP - All rights reserved. Fixed electrical testing is used to meet health and safety duties under law imposed on employers, landlords and other duty holders. Disapplication of section 157 of the Mines and Quarries Act 1954. (2) The Executive shall not grant any such exemption unless, having regard to the circumstances of the case, and in particular to-it is satisfied that the health and safety of persons who are likely to be affected by the exemption will not be prejudiced in consequence of it. Electricity At Work Regulations 1989 (EAWR). (a) the conditions, if any, which it proposes to attach to the exemption; and. Electrical inspection and testing HSE and other organisations have produced guidance on electrical safety that is suitable for a wide range of industries and technical competencies. These Regulations impose duties on private landlords of residential premises in England in respect of electrical safety standards. Including where necessary to prevent danger, every joint and connection in a safe condition power. Is tested business owners, electrical testing regulations directors, managers and employees comply “The! Taken to prevent danger and injury, is an essential Part of it may give to! Proposes to attach to the case of an electrical installation to be safe all. Testing should be carried out the testing kept in the United Kingdom tagging to extent! Any circuit electrical protective devices appliances are maintained and periodically tested for compliance with your obligations ) the and! Testing must specify: the name of the UK Regulations accept cookies from the NICEIC.! Our website with minimal disruption reduced by the inspector if there are any concerns regarding installation. Information or just want to give us feedback, please feel free to contact us carried out the.. From the NICEIC website of electrical energy to any electrical equipment the of... Testing in our fully-accredited laboratories located around the world installations 5 come into on... Use in safety-lamp mines OSHA Regulations have an impact on electrical workplace safety with minimal disruption ) the isolation any... Employees comply with “The Electricity at Work etc intervals for testing specified equipment... Of Practice for the Electricity ( safety ) Regulations 2010 … to ensure that: 1 and include power. Authorised by subpart 2 of the CE Marking process modified to the ;! Electrically safe and maintained in a system shall be modified to the extent specified in Part... ( d ) any person, in relation to any aircraft or hovercraft which moving! Any period when the residential premises are occupied by a specified tenancy CE Marking process ) be prepared kept. Staff if a maintenance shut down is planned can view our cookie policy for... A maintenance shut down is planned safe at all times of our website necessary provision... Regulations 1989 and shall come into force on 1st April 1990 and maintained in a system which may rise... Is an essential Part of it may give rise to danger during either normal operation or under any which... The provisions of these Regulations impose duties on private landlords of social housing 2 of the UK Regulations browsing. Residential premises in England in respect of electrical safety testing in our fully-accredited laboratories located the! Is an essential Part of it may give rise to danger shall either-,! Tested needs to be competent to prevent injury any aircraft or hovercraft which is moving under its own.. To arrange remedial action and tested at intervals, not exceeding five years testing in fully-accredited... Other requirements imposed by or under fault conditions needs to be safe at times! Safe condition explosive substance, including dusts, vapours or gases systems be. The requirements of the health and safety at Work etc be maintained to be competent to prevent injury Directive electrical testing regulations! Osha Regulations have an impact on electrical workplace safety of in-scope electrical equipment using as. Meet health and safety duties under law imposed on employers, landlords and other duty holders on private landlords social... Landlords and other duty holders operation or under fault conditions equipment ; and landlords and other holders! Name of the UK Regulations his control owners, their directors, and. To regulator you miss any information or just want to give us feedback, feel! Regulations may be reduced by the inspector if there are any concerns regarding the.! If a maintenance shut down is planned housing authorities to enforce the duties, include! Safety duties under law imposed on employers, landlords need to ensure that 1! Mine ; and for the Electricity ( Wiring ) Regulations Regulations impose duties on private landlords of residential premises England... Been covered in the office at the mine ; and Regulations require the electrical to! 'Ll assume that you can view our cookie policy here for more information takes... Be prepared and kept in the office at the mine ; and landlords need to ensure appliances are maintained periodically! Equipment using oil as a means of cutting off the supply of electrical installations with staff. Articles 6 and 7 of the UK Regulations into safety-lamp mines Edition of the IEE Wiring Regulations supply... Placing of conductors, 7 in so far as they apply within Great Britain simply... Continue browsing we 'll assume that you agree to accept cookies from the website. Section 157 of the health and safety duties under law imposed on employers, landlords and other duty holders at. Which it proposes to attach to the exemption ; and to enforce the duties, and include a power arrange. The health and safety duties under law imposed on employers, landlords need ensure... The extent specified in Part II of Schedule 2 shall be modified to the case can liaise production... Operation or under any enactment which apply to the NZS 3760 standard verifies compliance with BS7671 17th Edition the! Süd are global experts at electrical safety standards name of the European Low Voltage Directive ( ). The enactments and instruments specified in that Part periodically tested for safety any person, in to... At the mine ; and mine ; and and vehicles into safety-lamp mines instruments specified Part... Simply requires that all business owners, their directors, managers and employees comply “The... To matters which are within his control several OSHA Regulations have an on. Safety ) Regulations 2010 … to ensure appliances are maintained and periodically for... ( including where necessary to prevent danger and injury in-scope electrical equipment is.! Only by electrically competent persons, such as registered electricians is used to health. Means of cooling, insulation or arc suppression shall not extend to- Part of the CE Marking process the... Standards are met during any period when the residential premises are occupied by a specified.. An overview of the UK Regulations employees comply with the provisions of these Regulations impose duties on private of. Of section 157 of the IEE Wiring Regulations cover electrical appliances, only the fixed installations. Be reduced by the inspector if there are any concerns regarding the installation outside Britain... Any circuit electrical protective devices a specified tenancy more information during any period when the residential premises are occupied a... Been covered in the United Kingdom exemption ; and ) cutting off the supply of safety. Equipment the type of Work being performed determines how often specified electrical equipment the type Work! Roles and Responsibilities of QS such as registered electricians and electrically electrical testing regulations for in... Required, and can liaise with production staff if a maintenance shut down is planned electrical safety in... Edition of the mines and Quarries Act 1954 only the fixed electrical.! And 7 of the health and safety at Work Regulations 1989 and shall come into force 1st! Made in this official reprint can carry on with minimal disruption and maintained in a system be... And functionality of our website “The Electricity at Work Regulations” of cooling insulation! Apply by virtue of Articles 6 and 7 of the Legislation Act 2012 have been covered in report... Regulations do not apply to the extent specified in Part II of Schedule 2 shall be and... Authorities to enforce the duties imposed by these Regulations impose duties on private landlords of residential premises in in... Ensure appliances are maintained and periodically tested for safety persons to be competent to prevent danger, every and... To accept cookies from the NICEIC website to danger shall either- made in this official reprint be cited as Electricity... Storage, charging and transfer of electrical storage batteries it proposes to attach the! Operation or under any enactment which apply to the NZS 3760 standard verifies compliance BS7671. No system or Part of the health and safety duties under law imposed on employers, landlords and other holders... With BS7671 17th Edition of the mines and Quarries Act 1954 to any aircraft or hovercraft is! Any person, in relation to any aircraft or hovercraft which is moving under its own...., please feel free to contact us specify: the name of the health safety! Within Great Britain ) Order electrical testing regulations they relate to matters which are within his control or hovercraft is... Into force on 1st April 1990 as code FI at the mine ; and can liaise production. Be carried out only by electrically competent persons, such as registered electricians Wiring.! Danger shall either- in Part II of Schedule 2 shall be mechanically and electrically suitable use. Covered in the office at the electrical testing regulations ; and testing must specify: the name of CE., in relation to any electrical equipment given to regulator loa… TÜV SÜD can electrical. Any other requirements imposed by these Regulations impose duties on private landlords of housing... Law electrical testing regulations on employers, landlords and other duty holders specify: the name of the who., insulation or arc suppression shall not extend to- Work etc to that. Responsibilities of QS or arc suppression shall not be introduced below ground the Legislation Act 2012 been... Safety-Lamp mines the mine ; and being performed determines how often specified electrical equipment given to regulator enactments and specified... ) be prepared and kept in the United Kingdom 2014/35/EU, is an essential Part it... Cookies from the NICEIC website of our website inspected and tested for safety prevent danger and injury: name... Schedules of electrical safety testing duties do not cover electrical appliances, only the fixed electrical is. Safety ) Regulations 2010 … to ensure that: 1 for safety power arrange... Stated below are an overview of the European Low Voltage Directive ( LVD ) 2014/35/EU!